Comparison of Planar and 3-D Interdigitated Electrodes as Electrochemical Impedance Biosensors
- Lookup NU author(s)
- Dr Sunilkumar Rana
- Dr Robin Page
- Professor Calum McNeil
|
|
|
|
| Author(s) | | Rana S, Page RH, McNeil CJ |
| Publication type | | Article |
| Journal | | Electroanalysis |
| Year | | 2011 |
| Volume | | 23 |
| Issue | | 10 |
| Pages | | 2485-2490 |
| ISSN (print) | | 1040-0397 |
| ISSN (electronic) | | 1521-4109 |
|
|
|
| Full text for this publication is not currently held within this repository. Alternative links are provided below where available. |
|
|
|
|
| It has been reported that the introduction of a dielectric barrier between adjacent digits of an interdigitated electrode array can improve the sensitivity of the array as an electrochemical impedance biosensor. Here we present an in-depth analysis of the impedance in planar interdigitated electrodes and 3-D interdigitated electrodes (with dielectric barriers). The analysis indicates that the planar geometry not only provides lower impedance but also a higher change impedance as a result of molecular immobilization on the electrode array surface. |
|
|
|
| Publisher | | Wiley - V C H Verlag GmbH & Co. KGaA |
| URL | | http://dx.doi.org/10.1002/elan.201100353 |
| DOI | | 10.1002/elan.201100353 |
|
|
Actions | |  |