Toggle Main Menu Toggle Search

Open Access padlockePrints

Bioactive versus Bare Platinum Coils in the Treatment of Intracranial Aneurysms: The MAPS (Matrix and Platinum Science) Trial

Lookup NU author(s): Dr Anil Gholkar OBE

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

BACKGROUND AND PURPOSE: The ability of polymer-modified coils to promote stable aneurysm occlusion after endovascular treatment is not well-documented. Angiographic aneurysm recurrence is widely used as a surrogate for treatment failure, but studies documenting the correlation of angiographic recurrence with clinical failure are limited. This trial compares the effectiveness of Matrix(2) polyglycolic/polylactic acid biopolymer-modified coils with bare metal coils and correlates the angiographic findings with clinical failure (ie, target aneurysm recurrence), a composite end point that includes any incident of posttreatment aneurysm rupture, retreatment, or unexplained death.MATERIALS AND METHODS: This was a multicenter randomized noninferiority trial with blinded end point adjudication. We enrolled 626 patients, divided between Matrix(2) and bare metal coil groups. The primary outcome was target aneurysm recurrence at 12 +/- 3 months.RESULTS: At 455 days, at least 1 target aneurysm recurrence event had occurred in 14.6% of patients treated with bare metal coils and 13.3% of Matrix(2) (P = .76, log-rank test) patients; 92.8% of target aneurysm recurrence events were re-interventions for aneurysms that had not bled after treatment, and 5.8% of target aneurysm recurrence events resulted from hemorrhage or rehemorrhage, with or without retreatment. Symptomatic re-intervention occurred in only 4 (0.6%) patients. At 455 days, 95.8% of patients with unruptured aneurysms and 90.4% of those with ruptured aneurysms were independent (mRS <= 2). Target aneurysm recurrence was associated with incomplete initial angiographic aneurysm obliteration, presentation with rupture, and a larger aneurysmal dome and neck size.CONCLUSIONS: Tested Matrix(2) coils were not inferior to bare metal coils. Endovascular coiling of intracranial aneurysms was safe, and the rate of technical success was high. Target aneurysm recurrence is a promising clinical outcome measure that correlates well with established angiographic measurements.


Publication metadata

Author(s): McDougall CG, Johnston SC, Gholkar A, Barnwell SL, Suarez JCV, Romero JM, Chaloupka JC, Bonafe A, Wakhloo AK, Tampieri D, Dowd CF, Fox AJ, Imm SJ, Carroll K, Turk AS, MAPS Investigators

Publication type: Article

Publication status: Published

Journal: American Journal of Neuroradiology

Year: 2014

Volume: 35

Issue: 5

Pages: 935-942

Print publication date: 01/05/2014

Online publication date: 30/01/2014

ISSN (print): 0195-6108

ISSN (electronic): 1936-959X

Publisher: American Society of Neuroradiology

URL: http://dx.doi.org/10.3174/ajnr.A3857

DOI: 10.3174/ajnr.A3857

PubMed id: 24481333


Altmetrics

Altmetrics provided by Altmetric


Share