Toggle Main Menu Toggle Search

Open Access padlockePrints

Randomized controlled trial to assess the impact of continuous glucose monitoring on HbA(1c) in insulin-treated diabetes (MITRE Study)

Lookup NU author(s): Dr Jolanta Weaver

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

To determine whether continuous glucose information provided through use of either the GlucoWatch G2 Biographer or the MiniMed continuous glucose monitoring system (CGMS) results in improved glycated haemoglobin (HbA(1c)) for insulin-treated adults with diabetes mellitus, relative to an attention control and standard care group. Four hundred and four adults taking at least two daily insulin injections and with two consecutive HbA(1c) values >= 7.5% were recruited to this randomized controlled trial (RCT). All were trained at baseline to use the same monitor for traditional capillary glucose testing throughout the 18-month study. The CGMS group were asked to wear the device three times during the first 3 months of the trial and on another three occasions thereafter. The GlucoWatch group wore the device a minimum of four times per month and a maximum of four times per week during the first 3 months and as desired for the remainder of the trial. Trained diabetes research nurses used downloaded data to guide therapy adjustments. Proportional reduction in HbA(1c) from baseline to 18 months was the primary outcome measure. Neither an intention-to-treat nor per-protocol analysis showed improvement in HbA(1c) in the device groups compared with standard care. For the intention-to-treat analysis, when the standard care group was compared with each of the other groups, this equated to differences in mean relative HbA(1c) reduction (95% confidence interval) from baseline to 18 months of 3.5% (-1.3 to 8.3; GlucoWatch), 0.7% (-4.1 to 5.5; CGMS), and -0.1% (-4.6 to 4.3; attention control). The additional information provided by these devices did not result in improvements in HbA(1c) in this population.


Publication metadata

Author(s): Cooke D, Hurel SJ, Casbard A, Steed L, Walker S, Meredith S, Nunn AJ, Manca A, Sculpher M, Barnard M, Kerr D, Weaver JU, Ahlquist J, Newman SP

Publication type: Article

Publication status: Published

Journal: Diabetic Medicine

Year: 2009

Volume: 26

Issue: 5

Pages: 540-547

ISSN (print): 0742-3071

ISSN (electronic): 1464-5491

Publisher: Wiley-Blackwell Publishing Ltd.

URL: http://dx.doi.org/10.1111/j.1464-5491.2009.02723.x

DOI: 10.1111/j.1464-5491.2009.02723.x


Altmetrics

Altmetrics provided by Altmetric


Share