A novel method for continuous, non-invasive, cuff-less measurement of blood pressure: Evaluation in patients with non-alcoholic fatty liver disease

Lookup NU author(s): Dr James Orr, Dr Dave Houghton, Professor David Jones

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2016 IEEE.Objective: One promising approach for a continuous, non-invasive, cuff-less ambulatory BP monitor is to measure the pulse wave velocity or the inversely proportional pulse transit time (PTT), based on electrical and optical physiological measurements in the chest area. A device termed IsenseU-BP+ has been developed for measuring continuous BP, as well as other physiological data. The objective of this paper is to present results from the first clinical evaluation with a wide range of patients. The study was set up to verify whether IsenseU-BP+ can be used to measure raw signals with sufficient quality to derive PTT. Methods: The test protocol, run 23 times on 18 different patients with non-alcoholic fatty liver disease, includes both supine measurement at rest as well as measurements during indoor cycling. Changes in PTT were compared with the BP changes measured using validated reference sensors. Results: IsenseU-BP+ measured signals with good quality during rest on 17 of 18 patients despite the high diversity in age, body shape and BMI. Evaluation during cycling was difficult due to a lack of good reference measurements. Conclusion: IsenseU-BP+ measures PTT with high quality during supine rest and exercise and could therefore be suitable for deriving non-invasive continuous BP, although evaluation during exercise was limited due to inaccurate reference BP measurements. Significance: Continuous, non-invasive measurement of BP would be highly beneficial in a number of clinical settings. Systems currently considered gold-standard for the investigation of hypertension carry considerable limitations which could be overcome by the method proposed here.


Publication metadata

Author(s): Seeberg T, Orr J, Austad H, Roed M, Dalgard S, Houghton D, Jones D, Strisland F

Publication type: Article

Publication status: Published

Journal: IEEE Transactions on Biomedical Engineering

Year: 2017

Volume: 64

Issue: 7

Pages: 1469-1478

Print publication date: 01/07/2017

Online publication date: 12/09/2016

Acceptance date: 02/04/2016

ISSN (print): 0018-9294

ISSN (electronic): 1558-2531

Publisher: IEEE

URL: https://doi.org/10.1109/TBME.2016.2606538

DOI: 10.1109/TBME.2016.2606538


Altmetrics

Altmetrics provided by Altmetric


Share